DS-UPS02K48-R/TJS

Call for Price

SKU: DS-UPS02K48-R/TJS Categories: , , , , Tag: Brand:
  • Double conversion on-line design with input power factor correction (PFC) technology, achieving an input power factor of up to 0.99.
  • Digital control system for enhanced stability and reliability.
  • ECO operation mode for improved energy efficiency and reduced user costs.
  • Three-stage charging: constant current charging, constant voltage charging, and floating charging stages are intelligently managed.
  • Wide voltage input and frequency range for stable operation with different electrical scenario, and suit with various fuel generators.
  • Comprehensive protections including output overload, output short-circuit, over-temperature, battery under-voltage warning, battery over-charging protection, and power-on self-diagnostic function;
  • Power
  • UPS Capacity2000 VA / 1800 W
  • Input
  • Input Voltage Range110~300Vac (176~264Vac @ 100% load)
  • Input Frequency40~70Hz (50/60Hz Auto-Sensing)
  • Nominal Voltage208/220/230/240Vac
  • PhaseSingle Phase
  • Power factor≥0.99
  • Output
  • Output Frequency

    Online mode: 46~54Hz or 56~64Hz

    Bat. Mode: (50/60±0.1%)Hz

  • Transfer Time

    AC mode to Bat.mode: 0ms

    Inverter to Bypass: 4ms (Typical)

  • Output Voltage208/220/230/240Vac
  • Power factor0.9
  • Output SocketsIEC panel/EU panel/UK panel/US panel Optional
  • Crest factor3:1
  • Harmonic distortion (THDv)

    ≤3% Linear load

    ≤5% Non linear load

  • Output WaveformPure Sinewave
  • Battery
  • Battery TypeValve Regulated Lead Acid (VRLA)
  • Typical Recharging Time4 hours (To 90% of full capacity)
  • Capacity (Standard Unit)12V/9Ah
  • Battery Number4
  • DC System Voltage (VDC)48V
  • Charging Current (Max.)1A
  • Expandable RuntimeYes, External battery pack: DS-UPSB0948B-R/TJC
  • Indicator
  • AlarmBattery mode/Battery low voltage /Overload/Fault
  • LCD displayInput voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature & Remaining battery backup time
  • Efficiency
  • AC Mode91%
  • Battery Mode87%
  • Environment
  • Operating Temperature0°C~40°C
  • Storage Temperature-25°C~55°C
  • Humidity Range20~95%RH @ 0~40°C (Non condensing)
  • Altitude<1500m, derating required when>1500m
  • Noise Level<50dB at 1 Meter
  • Physical
  • Dimension W x D x H (mm)440 x 460 x 86.5
  • Net weight (kg)19.5
  • Standards
  • SafetyCE-LVD, IEC/EN 62040-1, IEC/EN 62477-1
  • EMCCE-EMC, IEC/EN 62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8

Description

  • Double conversion on-line design with input power factor correction (PFC) technology, achieving an input power factor of up to 0.99.
  • Digital control system for enhanced stability and reliability.
  • ECO operation mode for improved energy efficiency and reduced user costs.
  • Three-stage charging: constant current charging, constant voltage charging, and floating charging stages are intelligently managed.
  • Wide voltage input and frequency range for stable operation with different electrical scenario, and suit with various fuel generators.
  • Comprehensive protections including output overload, output short-circuit, over-temperature, battery under-voltage warning, battery over-charging protection, and power-on self-diagnostic function;